MODEL
FLHA
Filter
SERIES 3 / CAPACITY: 160 L/min. / CAVITY: T-16A
Sun filter elements are available as Surface Type (Last Chance) and Depth Style elements. The flow path is Port 2
to Port 1 and should not be used in reverse, even with a reverse free flow check valve installed. The elements have
a high collapse pressure and are intended to be used in line with the system. Filter life will depend on initial system
cleanliness and the amount of dirt ingression to the system when operating.
TECHNICAL DATA
Cavity T-16A
Series 3
Capacity 160 L/min.
Maximum Operating Pressure 350 bar
Valve Hex Size 31,8 mm
Valve Installation Torque 203 - 217 Nm
Seal kit - Cartridge Buna: 990016007
Seal kit - Cartridge EPDM: 990016014
Seal kit - Cartridge Polyurethane: 990016002
Seal kit - Cartridge Viton: 990016006
(X)CONTROL
X Not Adjustable
(D)FILTER RATING
D 40 Micron Nominal (Surface type)
A 3 Micron Nominal (Depth type)
B 10 Micron Nominal (Depth type)
C 25 Micron Nominal (Depth type)
(N)SEAL MATERIAL
N Buna-N
E EPDM
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
/LH Mild Steel, Zinc-Nickel
snhy.com/
FLHA
NOTES
Capacity rating is dependent on the micron rating of the element. Stated flow capacity in the Technical Data table is based on the 40 micron rating. See
performance curves.
See Related Accessories for replacement elements.
Model Code Example: FLHAXDNCONFIGURATION OPTIONS